{"product_id":"double-beam-uv-visible-spectrophotometer-sp-iuv8-sp-iuv9-high-precision-190-1100-nm-laboratory-spectrophotometer","title":"Double Beam UV-Visible Spectrophotometer SP-IUV8 \/ SP-IUV9 | High-Precision 190–1100 nm Laboratory Spectrophotometer","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eLABTECH Double Beam UV-Visible Spectrophotometer SP-IUV8 \/ SP-IUV9\u003c\/strong\u003e is a premium analytical instrument designed for demanding laboratory applications requiring exceptional precision, stability, and repeatability. Its advanced \u003cstrong\u003edouble beam optical system\u003c\/strong\u003e continuously compares the sample and reference beams, minimizing baseline drift while ensuring highly accurate analytical results.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFeaturing a high-performance \u003cstrong\u003eCzerny-Turner monochromator\u003c\/strong\u003e, \u003cstrong\u003e1600 lines\/mm diffraction grating\u003c\/strong\u003e, \u003cstrong\u003e8-inch color touchscreen\u003c\/strong\u003e, and powerful spectrum processing software, the instrument supports spectral scanning, multi-wavelength analysis, kinetic testing, derivative spectroscopy, quantitative analysis, and data storage. It is widely used in pharmaceutical laboratories, research institutes, environmental testing, biotechnology, food analysis, petrochemical laboratories, and quality control facilities.\u003c\/p\u003e\n\n\u003cstyle\u003e\n.labtech-spec-table{\nwidth:100%;\nborder-collapse:collapse;\nfont-family:Arial,Helvetica,sans-serif;\nfont-size:15px;\nbackground:#fff;\nborder-radius:12px;\noverflow:hidden;\nbox-shadow:0 6px 18px rgba(0,0,0,.08);\nmargin:25px 0;\n}\n\n.labtech-spec-table thead th{\nbackground:#1c5f91;\ncolor:#fff;\npadding:16px;\nfont-size:20px;\ntext-align:left;\n}\n\n.labtech-spec-table td{\npadding:14px 16px;\nborder-bottom:1px solid #e8edf2;\n}\n\n.labtech-spec-table tr:nth-child(even){\nbackground:#f8fbfd;\n}\n\n.labtech-spec-table tr:hover{\nbackground:#eef7fc;\n}\n\n.labtech-spec-table td:first-child{\nfont-weight:600;\ncolor:#1c5f91;\nwidth:38%;\n}\n\n@media(max-width:768px){\n\n.labtech-spec-table,\n.labtech-spec-table tbody,\n.labtech-spec-table tr,\n.labtech-spec-table td{\ndisplay:block;\nwidth:100%;\n}\n\n.labtech-spec-table thead{\ndisplay:none;\n}\n\n.labtech-spec-table tr{\nmargin-bottom:15px;\nborder:1px solid #dbe5ef;\nborder-radius:10px;\noverflow:hidden;\n}\n\n.labtech-spec-table td{\npadding:12px 15px;\n}\n\n.labtech-spec-table td:first-child{\nbackground:#1c5f91;\ncolor:#fff;\nfont-weight:700;\n}\n\n}\n\u003c\/style\u003e\n\n\u003ctable class=\"labtech-spec-table\"\u003e\n\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eTechnical Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eModels\u003c\/td\u003e\n\u003ctd\u003eSP-IUV8 \/ SP-IUV9\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhotometry\u003c\/td\u003e\n\u003ctd\u003eDouble Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eMonochromator Type\u003c\/td\u003e\n\u003ctd\u003eCzerny-Turner\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eFocal Length\u003c\/td\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eGrating\u003c\/td\u003e\n\u003ctd\u003e1600 lines\/mm Holographic Diffraction Grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd\u003e\nSP-IUV8: 1 nm or 2 nm\u003cbr\u003e\nSP-IUV9: 0.5, 1, 2, 4 or 5 nm\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e8-inch Color Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eWavelength Setting\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e190–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eScanning Speed\u003c\/td\u003e\n\u003ctd\u003eFast \/ Medium \/ Slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e≤0.02%T (220 nm NaI, 360 nm NaNO₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd\u003e\n0.0–200.0%T\u003cbr\u003e\n-0.301–4.000A\u003cbr\u003e\n0–9999C\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd\u003e\n±0.3%T\u003cbr\u003e\n±0.002 Abs (0–0.5A)\u003cbr\u003e\n±0.004 Abs (0.5–1A)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd\u003e\n≤0.15%T\u003cbr\u003e\n0.001 Abs (0–0.5A)\u003cbr\u003e\n0.002 Abs (0.5–1A)\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eBaseline Stability\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.0008A (200–1090 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e\n100%T ≤0.1%T\u003cbr\u003e\n0%T ≤0.02%T\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDrift\u003c\/td\u003e\n\u003ctd\u003e≤0.004 Abs\/hour (250 \u0026amp; 500 nm after 2-hour warm-up)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eLong-life Deuterium Lamp \u0026amp; Tungsten Halogen Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V ±22V, 50Hz ±1Hz, 200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eNet \/ Gross Weight\u003c\/td\u003e\n\u003ctd\u003e34 kg \/ 42.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInstrument Dimensions\u003c\/td\u003e\n\u003ctd\u003e584 × 504 × 360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd\u003e750 × 640 × 460 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003cstyle\u003e\n.download-btn {\n    display: inline-flex;\n    align-items: center;\n    justify-content: center;\n    gap: 10px;\n    padding: 14px 28px;\n    background: #1c5f91;\n    color: #ffffff !important;\n    text-decoration: none;\n    font-size: 16px;\n    font-weight: 600;\n    font-family: Arial, sans-serif;\n    border-radius: 8px;\n    transition: all 0.3s ease;\n    box-shadow: 0 6px 18px rgba(28, 95, 145, 0.25);\n}\n\n.download-btn:hover {\n    background: #154b72;\n    color: #ffffff !important;\n    transform: translateY(-2px);\n    box-shadow: 0 10px 24px rgba(28, 95, 145, 0.35);\n}\n\n.download-btn svg {\n    width: 20px;\n    height: 20px;\n    fill: #ffffff;\n}\n\n@media (max-width: 767px) {\n    .download-btn {\n        width: 100%;\n        padding: 14px 20px;\n    }\n}\n\u003c\/style\u003e\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/3711\/1180\/files\/Brochure-Spectrophotometer-26.7.7_1.pdf?v=1785583875\" class=\"download-btn\" target=\"_blank\" download\u003e\n\n    \u003csvg viewbox=\"0 0 24 24\"\u003e\n        \u003cpath d=\"M19 9h-4V3H9v6H5l7 7 7-7zm-14 9h14v2H5v-2z\"\u003e\u003c\/path\u003e\n    \u003c\/svg\u003e\n\n    \u003cspan\u003eDownload Brochure\u003c\/span\u003e\n\n\u003c\/a\u003e","brand":"LABTECH Pakistan","offers":[{"title":"Default Title","offer_id":51766651355276,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/3711\/1180\/files\/DoubleBeamUV-VisibleSpectrophotometerSP-IUV8SP-IUV9.webp?v=1785588407","url":"https:\/\/labtech.com.pk\/products\/double-beam-uv-visible-spectrophotometer-sp-iuv8-sp-iuv9-high-precision-190-1100-nm-laboratory-spectrophotometer","provider":"LABTECH Pakistan","version":"1.0","type":"link"}