{"title":"EWAI","description":null,"products":[{"product_id":"ewai-aa-7090-zeeman-aas-analyzer-for-trace-element-and-metal-analysis","title":"EWAI AA-7090 Zeeman AAS Analyzer for Trace Element and Metal Analysis","description":"\u003cp\u003eThe EWAI AA-7090 Zeeman Atomic Absorption Spectrophotometer is an advanced analytical instrument designed for accurate elemental analysis at normal and trace concentrations. Featuring longitudinal Zeeman background correction, a transverse-heated graphite furnace, and an integrated flame and graphite furnace design, the AA-7090 supports a wide range of analytical applications in research, industrial testing, and quality control laboratories.\u003cbr\u003eThe instrument incorporates an advanced optical system with an 1800 lines\/mm diffraction grating, a compact optical path, and automated switching between flame and graphite furnace atomization modes in less than two seconds. Its continuously adjustable magnetic field helps optimize background correction for different elements, while automated wavelength positioning, lamp selection, slit adjustment, and lamp-current optimization simplify routine operation.\u003cbr\u003eThe AA-7090 can analyze more than 70 elements, according to the manufacturer, and supports multiple analytical methods, including flame absorption, flame emission, graphite furnace, and hydride analysis. Its software provides calibration, concentration calculations, quality-control checks, data management, and report generation.\u003c\/p\u003e\n\n\n\u003cstyle\u003e\n  .labtech-specs {\n    width: 100%;\n    border-collapse: collapse;\n    font-family: Arial, sans-serif;\n    font-size: 14px;\n    color: #333333;\n    margin: 20px 0;\n    background: #ffffff;\n  }\n\n  .labtech-specs caption {\n    text-align: left;\n    font-size: 22px;\n    font-weight: 700;\n    color: #164b78;\n    padding-bottom: 14px;\n  }\n\n  .labtech-specs th,\n  .labtech-specs td {\n    border: 1px solid #d9e1e8;\n    padding: 12px 16px;\n    text-align: left;\n    vertical-align: top;\n    line-height: 1.6;\n  }\n\n  .labtech-specs thead th {\n    background: #164b78;\n    color: #ffffff;\n    font-weight: 600;\n  }\n\n  .labtech-specs tbody tr:nth-child(even) {\n    background: #f3f7fa;\n  }\n\n  .labtech-specs tbody tr:hover {\n    background: #e8f3fa;\n  }\n\n  .labtech-specs tbody td:first-child {\n    width: 42%;\n    font-weight: 600;\n    color: #164b78;\n  }\n\n  @media (max-width: 600px) {\n    .labtech-specs {\n      font-size: 12px;\n    }\n\n    .labtech-specs th,\n    .labtech-specs td {\n      padding: 8px;\n      overflow-wrap: anywhere;\n    }\n\n    .labtech-specs caption {\n      font-size: 19px;\n    }\n  }\n\u003c\/style\u003e\n\n\u003ctable class=\"labtech-specs\"\u003e\n  \u003ccaption\u003eTechnical Specifications – EWAI AA-7090\u003c\/caption\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n      \u003cth scope=\"col\"\u003eAA-7090\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstrument Type\u003c\/td\u003e\n      \u003ctd\u003eZeeman Atomic Absorption Spectrophotometer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWavelength Range\u003c\/td\u003e\n      \u003ctd\u003e190–900 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n      \u003ctd\u003e±0.1 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.05 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMonochromator\u003c\/td\u003e\n      \u003ctd\u003eCzerny–Turner grating monochromator\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiffraction Grating\u003c\/td\u003e\n      \u003ctd\u003e1800 lines\/mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBlazing Wavelength\u003c\/td\u003e\n      \u003ctd\u003e250 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n      \u003ctd\u003e0.1, 0.2, 0.4, 1.0, 2.0 nm; automatic switching\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003eBetter than 0.1 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStatic Baseline Stability\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.002 A \/ 30 min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDynamic Baseline Stability\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.003 A \/ 30 min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Copper Characteristic Concentration\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.02 μg\/mL\/1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Copper Detection Limit\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.003 μg\/mL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Precision\u003c\/td\u003e\n      \u003ctd\u003eRSD ≤ 0.45%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGraphite Furnace Cadmium Characteristic Amount\u003c\/td\u003e\n      \u003ctd\u003e0.5 × 10⁻¹² g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGraphite Furnace Cadmium Detection Limit\u003c\/td\u003e\n      \u003ctd\u003e1.0 × 10⁻¹² g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGraphite Furnace Temperature Range\u003c\/td\u003e\n      \u003ctd\u003eAmbient to 2700°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Graphite Furnace Heating Rate\u003c\/td\u003e\n      \u003ctd\u003e≥ 2500°C\/s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGraphite Furnace Temperature Control Precision\u003c\/td\u003e\n      \u003ctd\u003e≤ 1%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGraphite Furnace Temperature Repeatability\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackground Correction\u003c\/td\u003e\n      \u003ctd\u003eZeeman and D₂ lamp\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAnalytical Methods\u003c\/td\u003e\n      \u003ctd\u003eFlame absorption, flame emission, graphite furnace, and hydride methods\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIntegrated Instrument Dimensions\u003c\/td\u003e\n      \u003ctd\u003e1000 × 610 × 580 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e150 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003e220 V, 50 Hz, single-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstrument Power\u003c\/td\u003e\n      \u003ctd\u003e500 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGraphite Furnace Power\u003c\/td\u003e\n      \u003ctd\u003e4 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\n\u003cstyle\u003e\n  .labtech-brochure-btn {\n    display: inline-block;\n    background: linear-gradient(135deg, #164b78, #087fbd);\n    color: #ffffff !important;\n    padding: 14px 28px;\n    border: 2px solid #164b78;\n    border-radius: 6px;\n    text-decoration: none !important;\n    font-family: Arial, sans-serif;\n    font-size: 16px;\n    font-weight: 600;\n    text-align: center;\n    box-shadow: 0 4px 10px rgba(22, 75, 120, 0.18);\n    transition: all 0.3s ease;\n  }\n\n  .labtech-brochure-btn:hover {\n    background: #ffffff;\n    color: #164b78 !important;\n    border-color: #087fbd;\n    transform: translateY(-2px);\n    box-shadow: 0 6px 14px rgba(22, 75, 120, 0.25);\n  }\n\u003c\/style\u003e\n\n\u003ca class=\"labtech-brochure-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/3711\/1180\/files\/AAS_7090_with_Zeeman__D2_by_EWAI_Inc.pdf?v=1792231691\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\n  Download Brochure\n\u003c\/a\u003e\n","brand":"LABTECH Pakistan","offers":[{"title":"Default Title","offer_id":63085769949324,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/3711\/1180\/files\/AA-7090AtomicAbsorptionSpectrometer.webp?v=1792231348"},{"product_id":"ewai-aa-7050d-atomic-absorption-spectrophotometer-for-trace-element-analysis","title":"EWAI AA-7050D Atomic Absorption Spectrophotometer for Trace Element Analysis","description":"\u003cp\u003eThe EWAI AA-7050D Atomic Absorption Spectrophotometer is an analytical instrument designed for quantitative elemental analysis, including the measurement of trace and micro-level concentrations. It features a double-beam total-reflection optical system with automatic baseline compensation and real-time lamp drift correction to support stable analytical performance.\u003cbr\u003eThe AA-7050D automates key operations, including zero return, wavelength scanning, lamp positioning, mirror adjustment, and energy balancing according to the selected element and analytical method. Its computer-controlled eight-lamp turret enables automatic lamp selection, while six automatic spectral bandwidth settings provide flexibility for different analytical requirements.\u003cbr\u003eWith deuterium-lamp and self-reversal background correction methods, a high-sensitivity photomultiplier tube, and flame emission capability, the AA-7050D supports a broad range of laboratory testing applications. EWAI states that the instrument can analyze more than 70 elements.\u003c\/p\u003e\n\n\n\u003cstyle\u003e\n.labtech-specs {\n  width: 100%;\n  border-collapse: collapse;\n  font-family: Arial, sans-serif;\n  font-size: 14px;\n  color: #263746;\n  margin: 20px 0;\n  background: #ffffff;\n}\n.labtech-specs caption {\n  text-align: left;\n  font-size: 20px;\n  font-weight: 700;\n  color: #164b78;\n  padding: 12px 0;\n}\n.labtech-specs th {\n  background: #164b78;\n  color: #ffffff;\n  text-align: left;\n  padding: 13px 15px;\n  border: 1px solid #164b78;\n}\n.labtech-specs td {\n  padding: 11px 15px;\n  border: 1px solid #d9e1e8;\n  vertical-align: top;\n  line-height: 1.5;\n}\n.labtech-specs tbody tr:nth-child(even) {\n  background: #f3f7fa;\n}\n.labtech-specs tbody tr:hover {\n  background: #e8f3fa;\n}\n.labtech-specs td:first-child {\n  width: 36%;\n  font-weight: 600;\n  color: #164b78;\n}\n@media screen and (max-width: 600px) {\n  .labtech-specs {\n    font-size: 12px;\n  }\n  .labtech-specs th,\n  .labtech-specs td {\n    padding: 9px 8px;\n  }\n}\n\u003c\/style\u003e\n\n\u003ctable class=\"labtech-specs\"\u003e\n  \u003ccaption\u003eEWAI AA-7050D Atomic Absorption Spectrophotometer – Specifications\u003c\/caption\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eAA-7050D\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOptical System\u003c\/td\u003e\n      \u003ctd\u003eDouble-beam total reflection optical system\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElement Analysis\u003c\/td\u003e\n      \u003ctd\u003eCapable of analyzing more than 70 elements\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n      \u003ctd\u003eSix automatic slit settings: 0.1, 0.2, 0.4, 0.7, 1.0 and 2.0 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n      \u003ctd\u003e±0.1 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWavelength Repeatability\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.05 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpectral Resolution\u003c\/td\u003e\n      \u003ctd\u003eBetter than 0.1 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLamp Turret\u003c\/td\u003e\n      \u003ctd\u003eComputer-controlled 8-lamp turret\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLamp Operation\u003c\/td\u003e\n      \u003ctd\u003eAutomatic preheating of the next element lamp; supports operation of two lamps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBackground Correction\u003c\/td\u003e\n      \u003ctd\u003eD₂ lamp and self-reversal methods\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDetector\u003c\/td\u003e\n      \u003ctd\u003eHigh-sensitivity photomultiplier tube (PMT)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBaseline Stability – Dynamic\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.003 A \/ 30 min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBaseline Stability – Static\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.002 A \/ 30 min\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Cu Characteristic Concentration\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.02 μg\/mL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Cu Detection Limit\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 0.003 μg\/mL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Analysis Precision (RSD)\u003c\/td\u003e\n      \u003ctd\u003e≤ 0.45%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAutomatic Functions\u003c\/td\u003e\n      \u003ctd\u003ePeak search, zero return, scanning, lamp positioning, mirror adjustment and energy balancing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFlame Emission\u003c\/td\u003e\n      \u003ctd\u003eSupported\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApplications\u003c\/td\u003e\n      \u003ctd\u003eMetallurgy, petrochemicals, geology, medicine, environmental protection, scientific research, agriculture, disease control, food safety, materials science and commodity inspection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\n","brand":"LABTECH Pakistan","offers":[{"title":"Default Title","offer_id":63085770604684,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/3711\/1180\/files\/EWAIAA-7090LaboratoryAnalyzer.webp?v=1792232236"},{"product_id":"ewai-aa-7095-atomic-absorption-spectrophotometer-for-trace-element-analysis","title":"EWAI AA-7095 Atomic Absorption Spectrophotometer for Trace Element Analysis","description":"\u003ch3\u003e\u003cspan\u003eEWAI AA-7095 Atomic Absorption Spectrophotometer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWAI AA-7095 Atomic Absorption Spectrophotometer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an advanced analytical instrument designed for elemental analysis, including trace-element measurement in samples with complex matrices and significant background interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeaturing a fixed eight-lamp holder, a transversely heated graphite furnace, and dual background correction technologies, the AA-7095 supports analytical applications requiring reliable measurements and efficient multi-element workflows.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFixed 8-Lamp Holder:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Accommodates eight lamps with simultaneous preheating to help reduce waiting time between analyses.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTransversely Heated Graphite Furnace:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for graphite-furnace atomic absorption analysis.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDual Background Correction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Combines longitudinal AC Zeeman and deuterium (D₂) lamp background correction modes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Spectral Bandwidth Selection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Six settings—0.1, 0.2, 0.4, 0.7, 1.0, and 2.0 nm.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Slit-Height Switching:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatically adjusts slit height according to analytical requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic Peak Search:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Performs zero return, wavelength scanning, lamp positioning, mirror adjustment, and energy balancing automatically.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe AA-7095 is suitable for elemental analysis in:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmental monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFood safety and agricultural testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGeology and metallurgy\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eChemical and mechanical industries\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBiomedical and pharmaceutical laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaterials science and light industry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResearch and quality-control laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e\n.labtech-specs {\n  width: 100%;\n  border-collapse: collapse;\n  font-family: Arial, sans-serif;\n  font-size: 14px;\n  color: #263746;\n  margin: 20px 0;\n  background: #ffffff;\n}\n.labtech-specs caption {\n  text-align: left;\n  font-size: 20px;\n  font-weight: bold;\n  color: #164b78;\n  padding: 12px 0;\n}\n.labtech-specs thead th {\n  background: #164b78;\n  color: #ffffff;\n  text-align: left;\n  padding: 13px 15px;\n  border: 1px solid #164b78;\n}\n.labtech-specs td {\n  padding: 11px 15px;\n  border: 1px solid #d9e1e8;\n  vertical-align: top;\n  line-height: 1.5;\n}\n.labtech-specs tbody tr:nth-child(even) {\n  background: #f3f7fa;\n}\n.labtech-specs tbody tr:hover {\n  background: #e8f3fa;\n}\n.labtech-specs td:first-child {\n  width: 36%;\n  font-weight: 600;\n  color: #164b78;\n}\n@media screen and (max-width: 600px) {\n  .labtech-specs {\n    font-size: 12px;\n  }\n  .labtech-specs th,\n  .labtech-specs td {\n    padding: 9px 8px;\n  }\n}\n\u003c\/style\u003e\n\u003ctable class=\"labtech-specs\"\u003e\n\u003ccaption\u003eEWAI AA-7095 Atomic Absorption Spectrophotometer – Specifications\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEWAI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAA-7095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Type\u003c\/td\u003e\n\u003ctd\u003eAtomic Absorption Spectrophotometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Holder\u003c\/td\u003e\n\u003ctd\u003eFixed 8-lamp holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp Preheating\u003c\/td\u003e\n\u003ctd\u003eSimultaneous preheating of lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraphite Furnace\u003c\/td\u003e\n\u003ctd\u003eTransversely heated graphite furnace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackground Correction\u003c\/td\u003e\n\u003ctd\u003eLongitudinal AC Zeeman and deuterium (D₂) lamp correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd\u003eSix automatic settings: 0.1, 0.2, 0.4, 0.7, 1.0 and 2.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlit Height\u003c\/td\u003e\n\u003ctd\u003eAutomatic switching according to analytical requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Functions\u003c\/td\u003e\n\u003ctd\u003ePeak search, zero return, wavelength scanning, lamp positioning, mirror adjustment and energy balancing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis Technique\u003c\/td\u003e\n\u003ctd\u003eAtomic absorption with graphite-furnace capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplications\u003c\/td\u003e\n\u003ctd\u003eEnvironmental monitoring, food safety, agriculture, geology, metallurgy, chemical industries, biomedical laboratories, materials science and research\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"LABTECH Pakistan","offers":[{"title":"Default Title","offer_id":63086340931724,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/3711\/1180\/files\/EWAIAA-7095LaboratoryInstrument.webp?v=1792233692"}],"url":"https:\/\/labtech.com.pk\/collections\/ewai.oembed","provider":"LABTECH Pakistan","version":"1.0","type":"link"}